Hospital

Buxton Service, Inc. has supplied stand-by emergency generator systems for many commercial applications, including Welch's Fruit Juice, BJ Wholesalers, Perdue Farms, local hospitals, computer software manufacturers, and others.

Our line of commercial generator systems range from 20KW to 2,000KW and are available in natural gas, propane and diesel fuel. In addition, a complete line of accessories is available for all models, such as weatherproof enclosures, circuit breakers, fuel tanks, and transfer switches. To build a custom generator package that meets your specific company requirements, please call our office for assistance.

The chart below lists gas and diesel generators between 20KW and 200KW. If you wouldKohler 20KW Diesel like information on anything larger than a 150KW, click here to request literature. Click on the generator model you are interested in below to view specifications for that unit (in order to view the specs, you need Acrobat Reader, a free program from Adobe).

 

 

Commercial Gensets — NAT GAS and PROPANE
Model / Kilowatts Manufacturer Engine / Cylinders Horsepower Fuel Consumption
20RZ / 20KW Kohler Ford / 4 cyl 41 Nat Gas: 280 cu ft/hr
Propane: 120 cu ft/hr
SP25FN4 / 25KW Katolight Nissan / 4 cyl 43 Nat Gas: 270 cu ft/hr
Propane: 173 cu ft/hr
35RZG / 35KW Kohler GM / 6 cyl 75 Nat Gas: 584 cu ft/hr
Propane: 242 cu ft/hr
SP40FG4 / 40KW Katolight GM / 6 cyl 67 Nat Gas: 480 cu ft/hr
Propane: 191 cu ft/hr
45RZG / 45KW Kohler GM / 6 cyl 75 Nat Gas: 584 cu ft/hr
Propane: 246 cu ft/hr
SP50FG4 / 50KW Katolight GM / 8 cyl 85 Nat Gas: 698 cu ft/hr
Propane: 304 cu ft/hr
SP60FG4 / 60KW Katolight GM / 8 cyl 88 Nat Gas: 673 cu ft/hr
Propane: 269 cu ft/hr
SP80FG4 / 80KW Katolight GM / 8 cyl 150 Nat Gas: 1000 cu ft/hr
Propane: 459 cu ft/hr
SP100FG4 / 100KW Katolight GM / 8 cyl 162 Nat Gas: 1180 cu ft/hr
Propane: 602 cu ft/hr
100RZG / 100KW Kohler GM / 8 cyl 162 Nat Gas: 1164 cu ft/hr
Propane: 511 cu ft/hr
SP130FG4 / 130KW* Katolight GM / 8 cyl 210 Nat Gas: 1591 cu ft/hr
150RZD / 150KW Kohler Detroit / 4 cyl 260 Nat Gas: 1910 cu ft/hr
200RZD / 200KW Kohler Detroit / 6 cyl 340 Nat Gas: 2370 cu ft/hr
  * De-rates to 100KW at 120/240v single phase voltage.

Commercial Gensets — DIESEL
Model / Kilowatts Manufacturer Engine / Cylinders Horsepower Fuel Consumption
SP15FY4 / 15KW Katolight Yanmar / 4 cyl 24.7 1.5 gal/hr
SP40FJ4 / 40KW Katolight John Deere / 4 cyl 71 3.6 gal/hr
SP60FJ4 / 60KW Katolight John Deere / 4 cyl 100 4.9 gal/hr
SP75FJ4 / 75KW Katolight John Deere / 4cyl 113 5.4 gal/hr
SP105FJ4 / 105KW Katolight John Deere / 6 cyl 165 8.1 gal/hr
SP125FJ4 / 125KW Katolight John Deere / 6 cyl 190 9.3 gal/hr
SP150FJ4 / 150KW Katolight John Deere / 6 cyl 260 13 gal/hr
SP200FJ4 / 200KW Katolight John Deere / 6 cyl 347 17.1 gal/hr
SP230FJ4 / 230KW Katolight John Deere / 6 cyl 347 17.7 gal/hr
SP250FJ4 / 250KW Katolight John Deere / 6 cyl 402 17.6 gal/hr
SP275FJ4 / 275KW Katolight John Deere / 6 cyl 442 19.3 gal/hr
SP300FJ4 / 300KW Katolight John Deere / 6 cyl 483 20.3 gal/hr
SP375FJ4 / 375KW Katolight John Deere / 6 cyl 563 25.1 gal/hr
SP400FJ4 / 400KW Katolight John Deere / 6 cyl 617 30.9 gal/hr

Top of page

© 2002 Buxton Service, Inc. All Rights Reserved.    

 

 

 

 

Request A Quote Request Literature